10.3.7. Replacement of additional safety locks and relay of system of injection of fuel
Fig. 10.5. Additional safety locks and relay of system of injection of fuel
|
The arrangement of additional safety locks and the relay of system of injection is shown in fig. 10.5, their appointment is given in tab. 10.5.
Table 10.5 Purpose of Additional Safety Locks and Relay of System of Injection of Fuel
You will need a key "on 10".
1. Disconnect a wire from the minus plug of the rechargeable battery.
2. Remove facing of a box of airinflow (see. "Removal and installation of a lattice and facing of a box of airinflow").
3. Turn off a nut of fastening of the block of safety locks and the relay...
|
4.... also take the block from an airinflow box.
|
5. For replacement of the fused safety lock remove a protective cover...
|
6.... also take a safety lock from the contact socket of the block.
|
7. Install a safety lock of the same face value in the contact socket, as removed.
8. In need of replacement take the relay from the assembly block, shaking it here and there, and install the new relay.
9. Install the block of safety locks and the relay and facing of a box of airinflow as it should be, the return to removal.